The application of magnetic resonace elastography in the non-invasive diagnosis of hepatic fibrosis
-
摘要: 肝纤维化是各种慢性肝病进展至肝硬化的共同过程,由于临床运用有创肝病理学检查存在一定的局限性,因此运用无创检查对肝纤维化进行评价,对病情发展变化进行监测十分必要。目前弹性成像技术被认为是能够较好地评价肝纤维化的有效手段。最近研制开发的磁共振弹性成像技术对肝纤维化的评估具有良好的应用前景。本文综述了该技术在肝纤维化诊断中的应用。Abstract: Hepatic fibrosis caused by chronic liver disease with different pathogenesis commonly progresses to liver cirrhosis.As the invasive diagnosis has limitations in clinical practice,the non-invasive method is essential for the assessment of hepatic fibrosis and monitoring of the progress of the disease.The elastography has been considered as an effective method in evaluating hepatic fibrosis.The recently developed magnetic resonance elastography has good application prospect in assessing hepatic fibrosis.This article reviewed the application of magnetic resonance elastography in the diagnosis of hepatic fibrosis.
-
[1]Cheng Y,Ping J,Xu L.Effects of curcumin on peroxisome proliferator-activated receptor gamma expression and nuclear translocation/redistribution in culture-activated rat hepatic stellate cells[J].Chin Med J(Engl),2007,120(9):794-801. [2]Friedman SL,Bansal MB.Reversal of hepatic fibrosis-fact or fantasy?[J].Hepatology,2006,43(Suppl 1):S82-88. [3]Regev A,Berho M,Jeffer LJ,et al.Sampling error and intra-observer variation in liver biopsy in patients with chronic HCV infection[J].Am J Gastroenterol,2002,97(10):2614-2618. [4]Faria SC,Ganesan K,Mwangi I,et al.MR imaging of liver fibrosis:current state of the art[J].Radiographics,2009,29(6):1615-1635. [5]Muthupillae R,Lomas DJ,Rossman PJ,et al.Magnetic resonance elastography by direct visualization of propagating acoustic strain waves[J].Science,1995,269(5232):1854-1857. [6]Huwart L,van Beers BE.MR elastography[J].Gastroenterol Clin Bio,2008,32:68-72. [7]Huwart L,Peeters F,Sinkus R,et al.Liver fibrosis:non-invasive assessment with MR elastography[J].NMR Biomed,2006,19(6 Suppl 1):173-179. [8]Huwart L,Sempoux C,Vicaut E,et al.Magnetic resonance elastography for the noninvasive staging of liver fibrosis[J].Gastroenterology,2008,135(1):32-40. [9]Hines CD,Bley TA,Lindstrom MJ,et al.Repeatability of magnetic resonance elastography for quantification of hepatic stiffness[J].J Magn Reson Imaging,2010,31(3):725-731. [10]Yin M,Talwalkar JA,Ehman RL,et al.Assessment of hepatic fibrosis with magnetic resonance elastography[J].Clin Gastroenterol Hepatol,2007,5(10):1207-1213. [11]Salameh N,Peeters F,Sinkus R,et al.Hepatic viscoelastic parameters measured with MR elastography:correlations with quantitative analysis of liver fibrosis in the rat[J].J Magn Reson Imaging,2007,26(4):956-962. [12]Yin M,Woollard J,Wang X,et al.Quantitative assessment of hepatic fibrosis in an animal model with magnetic resonance elastography[J].Magn Reson Med,2007,58(2):346-353. [13]Salameh N,Larrat B,Abarca-Quinones J,et al.Early detection of steatohepatitis in fatty rat liver by using MR elastography[J].Radiology,2009,253(1):90-97. [14]Ehman RL.Science to practice:can MR elastography be used to detect early steatohepatitis in fatty liver disease?[J].Radiology,2009,253(1):1-3. [15]Schwenzer NF,Springer F,Schraml C,et al.Non-invasive assessment and quantification of liver steatosis by ultrasound,computed tomography and magnetic resonance[J].J Hepatol,2009,51(3):433-445. [16]Georges PC,Hui JJ,Gombos Z,et al.Increased stiffness of the rat liver precedes matrix deposition:implications for fibrosis[J].Am J Physiol Gastrointes Liver Physiol,2007,293(6):G1147-1154. [17]Huwart L,Sempoux C,Salameh N,et al.Liver fibrosis:noninvasive assessment with MR elastography versus aspartate aminotransferase to platetet ratio index[J].Radiology,2007,245:(2)458-466. [18]Millonig G,Friedrich S,Adolf S,et al.Liver stiffness is directly influenced by central venous pressure[J].J Hepatol,2010,52(2):206-210. [19]Oudry J,Chen J,Glaser KJ,et al.Cross-validation of magnetic resonance elastography and ultrasound-based transient elastography:a preliminary phantom study[J].J Magn Reson Imaging,2009,30(5):1145-1150.
本文二维码
计量
- 文章访问数: 5438
- HTML全文浏览量: 22
- PDF下载量: 1400
- 被引次数: 0